Completing the Bus Device Configuration on Net Bridge
This section describes how to finalize the bus device configuration on the Net Bridge.
Make sure that you have:
- Connected all bus devices.
- Prepared the Net Bridge. See Preparing N500 Net Bridges.
Proceed as follows.
- Switch the Net Bridge MODE switch to SETUP.
- Ensure that the Net Bridge switch is ON.
- Wait for three seconds.
- Switch the Net Bridge MODE switch to OPERATING.
-
An internal test procedure is started.
Observe the green FUNC led for approximately one minute until the Net Bridge has saved the bus configuration. Check that:
- The green FUNC led blinks as many times as there are devices on the main bus.
- After a pause, the green FUNC led blinks as many times as there are devices on the reader buses.
- After a pause, the green FUNC led blinks as many times as there are lock cylinders connected on Door Modules.
Saving the bus configuration ends when the FUNC led is constantly illuminated green.
The procedure ends when constant green FUNC, RS-485 STATUS, SYSTEM STATUS, and SERVER CONN. leds are illuminated.
-
Check that the Door Module POWER, DEVICE, BRIDGE and SERVER leds are
illuminated green in all door modules.
Check also that the topmost led is illuminated green on all Key programming Hot Spots.
- Deployment may require additional configuration on iLOQ 5 Series Manager according to the Quick Guides.